DIT

DIT rugged displays and KVM rack drawers: MIL-SPEC models designed to meet MIL-STD-810 and MIL-STD-901

DIT (Display Integration Technologies), of Oceanside, California, builds rugged COTS displays: MIL-SPEC KVM rack drawers, multi-display and pivot drawers, flex, panel and touch monitors, field monitors and panel PCs. DIT lists its MIL-SPEC lines as designed to meet MIL-STD-810, MIL-STD-901 and MIL-STD-461, with the revision set by model (for example 810F/G or 901E). NewTec Reps represents DIT (Display Integration Technologies).

Overview

Who is DIT (Display Integration Technologies)?

DIT, which brands its website and catalogs DITHD, builds rugged displays in Oceanside, California. Its home page says it operates under the Electro Mechanical Assembly division of 2s2, Inc., an electronics contract manufacturer founded in Orange County in 1997 (DIT About page). DIT states that all its monitors are built at the Oceanside facility and are TAA compliant, and publishes CAGE code 787R6.

DIT calls itself a COTS (commercial off-the-shelf) solutions provider. Its military catalog numbers every military monitor as a Modified COTS (MCOTS) product and cites over 25 years of building rugged monitors in the United States.

How DIT builds a display

Each unit is assembled from interchangeable parts: an LCD module, a V-series video controller, a keyboard and pointer, an optional KVM switch back, a front face and a lens. Options include optical bonding, ITO EMI glass, heated glass, NVIS backlighting, high brightness above 1000 nits, PCAP or resistive touch and conformal coating (DIT reference catalog). In a DIT part number, "xx" stands for the options chosen. Size codes follow a pattern: 173W is a 17.3 in wide LCD and 238U a 23.8 in 4K UHD LCD.

What MIL-SPEC means in DIT's literature

DIT designs its MIL-SPEC lines to meet MIL-STD-810 (environment, vibration and shock), MIL-STD-901 (shipboard shock), MIL-STD-167 (shipboard vibration) and MIL-STD-461 (EMI), with revisions and methods set to the customer's requirement. The MD320Mx datasheet ties DIT's guarantee that a unit will pass to MIL-STD testing purchased through DIT and its partner third-party labs. If the program needs test reports, put the testing on the quote.

Does DIT publish NSNs?

Yes, for configured units. DIT's NSN page lists 5999-01-688-4473, 7010-01-623-0327 and 7025-01-656-7508 for RD1U-CAT24xx configurations and 7025-01-710-3249 for a PDD1-T2420L configuration.

Products and manufacturers

NewTec Reps represents DIT (Display Integration Technologies). NewTec Reps represents Epsilon Systems, including its AP West (Advanced Products Group West) displays.

ManufacturerStrongest atPart numbersNewTec Reps page
DITOperator stations from configurable COTS parts: KVM, multi-display and pivot drawers, MIL-SPEC monitors, field monitors, panel PCsMR, MGP, RD1U, RD2U, PDD3-F, PDD1-T, MP, RDKB, KVMS, MM, MT, MD, MMR, DTS and PPC seriesThis page
Epsilon Systems AP WestRuggedized flat panel displays; five of the seven REP datasheets list MIL-STD-901D Grade A, Class I, Type A shock; custom sizes up to 46 inREP-10LED-PM, REP-10CPU-PM, REP-15IFL-115VAC, REP-17IFL-115VAC, REP-19LCD-RM115, REP-21HDW-115TV, REP-24HDW-10U115TV; custom RFPD configured to order

Start with DIT when the requirement begins at the rack: a keyboard, a KVM switch and one to four screens in 1U to 4U. Start with Epsilon AP West for a standalone panel, rack or console display whose datasheet lists MIL-STD-901D Grade A shock and MIL-STD-167-1 vibration, or for a custom size.

Territory and export

NewTec Reps covers the Mid-Atlantic region (Maryland, Virginia, Washington DC and Delaware) and takes inquiries from programs anywhere, where export rules allow. DIT does not publish export classifications, so for a program outside the United States NewTec Reps asks DIT to classify the exact configuration before any quote. See export compliance for how EAR and ITAR rules apply.

Specifications

From DIT's product pages, datasheets and catalogs, retrieved November 24, 2026. The part number index links each part number to its DIT page.

Rack drawers, consoles and KVM switch backs

FamilyPart numbersKey data DIT publishesSource
MIL-SPEC KVM rack drawers (MR)MR17xx, MR19xx, MR20xx, MR24xx, MR224xx1U, or 2U split (MR224xx); 15 to 19 in LCDs; KVM backs to 16-port VGA (MR20xx), 16-port HDMI (MR224xx) or 32-port RJ45 (MR24xx); C300 friction slides; 1U models list shock and vibration design to MIL-STD-810G, MIL-STD-901D and MIL-STD-167
MIL-SPEC mobile graphics platform (MGP)MGP173MxPortable KVM console, 17.3 in FHD (1000 nits) or UHD (1300 nits); IP65 keyboard and chassis; designed to meet MIL-STD-810F/G, MIL-STD-901E Grade A or B and MIL-STD-461F/G; about 22 lb, 40 to 50 W
Clamshell KVM drawers (RD1U-CAT, RD1U-CxT)RD1U-CAT17xx, RD1U-CAT20xx, RD1U-CAT24xx, RD1U-CxTxx1U; the CAT number is depth in inches; CxT opens left (CLT) or right (CRT), 24 or 26 in deep; RD1U-CAT24xx: 32-port RJ45 KVM option, CAC reader, 12, 24 or 125 VDC
Lay-flat KVM drawers (RD1U-F)RD1U-F27xx, RD1U-F30xx, RD1U-F32xx1U; 20.1 in UXGA 1600 x 1200 monitor lays flat; 27, 30 or 32 in deep
Split-display drawers (RD1U-S, RD2U-S)RD1U-S20xx, RD2U-S20xx, RD2U-S24xxKeyboard and display move independently; 1U or 2U; 15 to 19 in; 8-port DVI or 16-port HDMI backs (RD2U-S24xx)
HYDRA multi-head drawers (PDD3-F)PDD3-F18xx, PDD3-F20xx, PDD3-F22xx, PDD3-F26xx, PDD3-Fxx173WTwo to four 17.2 to 21.5 in screens, up to UHD; 2U to 4U; 18 to 26 in deep
Pivot display drawers (PDD1-T)PDD1-T20xx, PDD1-T2420L1U; display slides out and rotates up to 120 degrees (PDD1-T20xx) or 125 degrees (PDD1-T2420L); 17.1 to 20.1 in
MIL-SPEC pivot display drawers (MP)MP1xx, MP2xx, MP3xx1U, 17.3 in FHD or 19 in SXGA; about 32 lb; 9 to 36 VDC; designed to meet MIL-STD-810F/G methods 500.4, 501.5, 507.4, 514.6 and 516.6 and MIL-STD-461F/G CE102, RE102. DIT does not say how the three differ
Rack drawer keyboards (RDKB)RDKB-T17, RDKB-T20, RDKB-T24, RDKB-T26, RDKB-R17T series takes 4 or 8-port KVM backs; RDKB-R17 has sealed silicone keyboards for marine, oil field and milling sites
KVM switch backs (KVMS)KVMS-D1, KVMS-D3, KVMS-D4, KVMS-E2, KVMS-E3.1, KVMS-E4, KVMS-G2, KVMS-G3, KVMS-I8, KVMS-I16, KVMS-K1, KVMS-O2, KVMS-O3.1, KVMS-O4, KVMS-O4.2, KVMS-O8.24 to 16 ports of DisplayPort (D), VGA (E, K), DVI (G), RJ45 (I) or HDMI (O); CAC port on KVMS-D3, KVMS-D4 and KVMS-G2

Monitors and panel PCs

FamilyPart numbersKey data DIT publishesSource
MIL-SPEC flex-mount monitors (MM)MM15Mx, MM17Mx, MM19Mx, MM215Mx, MM156Ex, MM238Mx, MM320Mx, MM430Mx, MM550Mx15 to 55 in, UHD from 23.8 in; VESA, rack, panel or flush mount; IP67 front and optically bonded lens on most; MM156Ex: IP65 / NEMA 4, -30 to +85 C, DIT lists MIL-STD-810E/G
MIL-SPEC tactical touch monitors (MT)MT320Mx, MT430Mx, MT550Mx43 in UHD on the MT430Mx page, 32 and 55 in by DIT's size code; bonded ITO PCAP touch standard; IP67 front; touch versions may not pass all MIL-STD-461 requirements (military catalog)
MIL-SPEC panel and bulkhead monitors (MD)MD238Mx, MD320Mx, MD430MxFace rises 3/8 to 1/2 in off the panel; EMI ITO lens; MD320Mx: 32 in UHD, about 85 lb, designed to meet MIL-STD-810F/G, MIL-STD-901E Grade A or B and MIL-STD-461F/G
Rugged field monitors (MMR)MMR-Q101HB, MMR-Q156HB, MMR-Q173HB, MMR-Q220HB, MMR-D101HB, MMR-D156HB, MMR-D173HB, MMR-D220HB, MMR-U238xN, MMR-U320xN10.1 to 32 in; MMR-Q entry level, 1000 to 1500 nits; MMR-D waveform and vector scope, 3G-SDI; MMR-U 4K with HDMI, DisplayPort and SDI (SDI optional on MMR-U320xN); battery mounts
Rack and on-rack monitors (DTS)DTS-RAxx, DTS-RA320U, DTS-RSxx, DTS-OR215W, DTS-OR238U, DTS-OR240W8U to 17U, 17 to 32 in; DTS-RA320U: 32 in portrait 4K, PCAP touch; DTS-OR215W and DTS-OR240W for broadcast and studio racks
Panel-mount and open-frame monitors (DTS)DTS-PMxx, DTS-PM19LC, DTS-OF121E, DTS_OF156EIP67 front panel mount, 15 to 19 in; open frame 12.1 or 15.6 in, PCAP, -30 to +85 C, 12 VDC
Panel PCs (PPC)PPC-PM121LC, PPC-SS15L1, PPC-SS15L2, PPC-SS15LO, PPC-SS19L1, PPC-SS220W1, PPC-SS220W2, PPC-IN10L1, PPC-IN15L1, PPC-IN15L2, PPC-IN19L1, PPC-IN220W1, PPC-EXP15L1, PPC-EXP220W110 to 21.5 in, Intel Atom to Core i5 processors, Core i7 options on some; PPC-SS stainless or outdoor, IP69K; PPC-IN IP66 front; PPC-EXP: DIT lists C1D2, C2D2, ATEX Zone 2 and IECEx, IP66 / NEMA 4X, -20 to +60 C

How to choose

Decide where the operator works and how many computers the station controls.

  • KVM rack drawer for a rack position. A KVM rack drawer (MR, RD1U, RD2U-S) puts one screen, a keyboard and an optional KVM switch back for up to 32 computers in 1U or 2U. MR is DIT's MIL-SPEC drawer; most RD pages list friction slides rather than MIL-STD numbers.
  • Multi-display drawer when one operator watches several feeds. A HYDRA drawer (PDD3-F) puts two to four screens in 2U to 4U.
  • MIL-SPEC monitor for a console, bulkhead or arm: MM for flexible mounting, MD for panel and bulkhead, MT for large-format touch.
  • Field monitor when the display travels: MMR series, or the MGP173Mx console on a ship deck.
  • Panel PC when the display needs its own computer: PPC-IN for industrial panels, PPC-SS where the enclosure must be IP69K, PPC-EXP for hazardous locations as DIT rates them.

Selection matrix

RequirementDIT models
1U KVM drawer with MIL-STD-901D shock and vibration designMR17xx, MR19xx, MR20xx, MR24xx
Up to 32 computers over RJ45MR24xx, RD1U-CAT24xx, RD1U-CxTxx
Keyboard and display that move independentlyMR224xx, RD1U-S20xx, RD2U-S20xx, RD2U-S24xx
Drawer 20 in deep or lessRD1U-CAT17xx, PDD3-F18xx, RD1U-CAT20xx, PDD3-F20xx, PDD3-Fxx173W (20 in version), MP1xx, MP2xx, MP3xx
Panel or bulkhead monitor with MIL-STD-901E shock designMD320Mx
Large-format 4K touchMT320Mx, MT430Mx, MT550Mx, DTS-RA320U
-30 to +85 C operationMM156Ex, MMR-Q156HB, DTS-OF121E, DTS_OF156E
CAC card reader or CAC portRD1U-CAT24xx (reader); KVMS-D3, KVMS-D4, KVMS-G2 (port)

Before you ask for a quote

  • Test evidence. If the program needs reports, buy the testing through DIT. Weigh touch against EMI on MT models.
  • Lens. NVIS for night vision equipment, optical bonding for Grade A shock, 461G EMI-ITO glass, heated glass or high bright.
  • Power. C90 2-pin inlet on the 1U MR models; 12, 24 or 125 VDC on RD1U-CAT24xx; 9 to 36 VDC on RD1U-CxTxx and MP.

Applications

  • Shipboard racks, consoles, bulkheads and decks: the 1U MR drawers, the MD320Mx and the MGP173Mx, whose DIT pages cite MIL-STD-901 shock design.
  • Transit cases: RD1U, RD2U-S and HYDRA drawers.
  • Multi-screen operator positions: HYDRA drawers; large-format touch: MT monitors.
  • Server rooms and data centers: RD1U drawers with KVMS backs.
  • Broadcast and studio racks: DTS-OR215W and DTS-OR240W monitors, MMR-D waveform monitors.
  • Broadcast, film, fire, police, search and rescue and drone field work: MMR monitors.
  • Marine, oil field and milling sites: RDKB-R17 sealed keyboard drawers.
  • Industrial panels: PPC-IN and PPC-SS; hazardous locations as DIT rates them: PPC-EXP.

Frequently asked questions

Does NewTec Reps represent DIT (Display Integration Technologies)?

Yes. NewTec Reps represents DIT (Display Integration Technologies). It covers the Mid-Atlantic region (Maryland, Virginia, Washington DC and Delaware) and takes inquiries from programs anywhere, where export rules allow.

Are DIT displays tested to MIL-STD-810 and MIL-STD-901?

DIT designs its MIL-SPEC lines to meet MIL-STD-810, MIL-STD-901, MIL-STD-167 and MIL-STD-461, with revisions and methods set to the customer's requirement. DIT ties its guarantee that a unit will pass to MIL-STD testing purchased through DIT and its partner third-party labs. If the program needs test reports, put the testing on the quote.

What does "xx" mean in a DIT part number?

In a DIT part number, "xx" stands for the options chosen, such as the LCD, keyboard, KVM back and lens. Size codes follow a pattern: 173W is a 17.3 in wide LCD and 238U a 23.8 in 4K UHD LCD. Send the base part number and the options you need, and NewTec Reps gets the configured number and quote from DIT.

What is the difference between a DIT KVM rack drawer and a HYDRA drawer?

A KVM rack drawer (MR, RD1U, RD2U-S) puts one screen, a keyboard and an optional KVM switch back for up to 32 computers in 1U or 2U. A HYDRA drawer (PDD3-F) puts two to four screens in 2U to 4U.

Can I order an evaluation unit of a DIT display?

Yes. Evaluation units of DIT displays, rack drawers and panel PCs are purchased through NewTec Reps, the same way as production quantities. Speak to an Engineer for a quote.

Have a requirement or a part number?

Speak to an Engineer who knows these product lines. Send what you have, even if it is only a rough spec, and we will come back with the models that fit.

Send the DIT part number, or the rack depth, screen count and size, the computers to switch, input power and the MIL-STDs the program calls for.

Speak to an Engineer

Talk through your requirement with an engineer

Tell us what you are building and what it has to survive. It is fine to come early, while the requirement is still open. We will match it to the right DIT (Display Integration Technologies) model, check the standards and interfaces, and get you a quote from the manufacturer when you are ready for one.

Fields marked * are required.

A part number, a rough spec or a question is enough.
Add company and other details (optional)

We use your details only to answer this request and may share them with the manufacturer you ask about. Privacy policy.