Rugged embedded hardware

MIL-STD COTS hardware: which standards apply and which products meet them

MIL-STD COTS hardware is commercial off-the-shelf (COTS) equipment that its manufacturer has designed, tested or qualified to U.S. military standards such as MIL-STD-810, MIL-STD-461, MIL-STD-1275 and MIL-STD-1553. This page explains what each standard covers and maps the models from the manufacturers NewTec Reps represents to the standards their own datasheets cite.

Overview

What MIL-STD COTS means

A MIL-STD is a U.S. Department of Defense standard: a test method, an interface definition or a set of limits that equipment must meet on a given platform. MIL-STD COTS hardware is a catalog product that already carries that work. The manufacturer has designed the unit to the standard, tested it, or qualified it, and says which.

Why programs buy it

A program that buys a qualified catalog part skips the design and qualification cycle of a custom unit, gets test data that already exists and buys a product that other programs also use and the manufacturer keeps supporting. The trade-off is that you accept the manufacturer's tailoring, revision letter and form factor. When those do not match the platform, the options are a delta test, a modified version of the COTS product or a custom design.

MIL-STD-810: environmental test methods

MIL-STD-810 is a library of laboratory test methods for temperature, humidity, altitude, sand and dust, rain, shock and vibration. A program tailors which methods apply and at what levels, so the standard by itself is not a pass or fail test. Datasheets in this catalog cite 810E, 810G, 810H or the standard without a letter. It applies to anything deployed: computers, switches, enclosures, displays and power.

MIL-STD-461: electromagnetic interference

MIL-STD-461 sets limits on conducted emissions and susceptibility on power and signal leads (CE101, CE102, CS101, CS114, CS116) and on radiated emissions and susceptibility (RE102, RS103). Which requirements apply, and at what limits, depends on the platform. Datasheets in this catalog cite 461E, 461F or the standard without a letter.

MIL-STD-704: aircraft electric power

MIL-STD-704 defines the power an aircraft delivers to equipment, including 28 VDC, 270 VDC and 115 VAC 400 Hz, with limits for normal, abnormal and transient conditions and power interruptions. Equipment that must ride through a bus transfer needs hold-up energy; Dawn VME Products' VPX hold-up modules supply 50 ms.

MIL-STD-1275: ground vehicle 28 VDC power

MIL-STD-1275 defines 28 VDC power on military ground vehicles: steady-state limits, surges, spikes and starting disturbances. Computers, switches and inverters that run from a vehicle bus need input protection and conditioning to it.

MIL-STD-1399: shipboard power interface

MIL-STD-1399 is the interface standard for shipboard systems; Section 300 covers AC electric power, including voltage and frequency tolerances. It applies to shipboard UPS, frequency converters and the filters on their inputs.

MIL-S-901D (MIL-STD-901D): shipboard high-impact shock

MIL-S-901D covers high-impact shock qualification of shipboard equipment. Grade A items must keep working after the shock, Class I means hard mounted without resilient mounts, and Type A is a principal unit. MIL-DTL-901E has since superseded 901D, and many datasheets still cite 901D; manufacturers write it as MIL-S-901D or MIL-STD-901D.

MIL-STD-167-1: shipboard vibration

MIL-STD-167-1 covers mechanical vibration of shipboard equipment. Type I is environmental vibration from the ship's propulsion and sea conditions; Type II is vibration excited inside the equipment by rotating machinery.

MIL-STD-202: component test methods

MIL-STD-202 is a set of test methods for electronic and electrical component parts, including shock and vibration. Board makers use it to state board-level ruggedness; Diamond Systems cites it for its switch boards and for the electronics inside its SabreCom computers.

RTCA DO-160: airborne equipment

RTCA DO-160 sets environmental conditions and test procedures for airborne equipment. It is a civil aviation document, not a MIL-STD, but airborne requirements often list it next to MIL-STD-810 and MIL-STD-461.

MIL-STD-1553, MIL-STD-1397 and MIL-STD-188-203-1A: interface standards

These define how equipment talks, not what it survives. MIL-STD-1553 is a dual-redundant 1 Mbps command and response databus with one bus controller and up to 31 remote terminals, used on military aircraft and vehicles. MIL-STD-1397 defines the Navy Tactical Data System (NTDS) parallel and serial interfaces. MIL-STD-188-203-1A defines the ATDS data link interface, also called TADIL-A.

When the governing standard is VITA or SOSA

Boards, backplanes and plug-in power are usually specified against VITA standards, not a MIL-STD: VITA 46 and VITA 65 for VPX and OpenVPX, VITA 47 for the environmental classes of plug-in modules, VITA 48 for cooling, VITA 62 for VPX power and VITA 90 for VNX+, with the SOSA technical standard on top. The chassis around them carries the MIL-STD qualification. See VPX and OpenVPX hardware and SOSA vs MOSA vs OpenVPX.

Other military specifications on these datasheets

MIL-DTL-38999 circular connectors appear on Diamond Systems SabreCom and SabreNet systems and on GET Engineering CEN-6300 and CEN-3300 systems. GET Engineering quotes MTBF for some NTDS adapters under MIL-HDBK-217.

Products and manufacturers

Each cell keeps the manufacturer's own wording. "Designed to meet", "designed to", "tested to", "passed" and "meets" are the manufacturer's verbs. "Listed" means the datasheet or product page names the standard without a verb. "Offered" means the manufacturer offers ruggedization to that standard as an option. "Line" means Nova Electric cites the standard for the product line, not for each model. Every model named here is in the part number index with a link to the manufacturer's own page.

Environment, shock and vibration

Product family and manufacturerMIL-STD-810MIL-STD-202MIL-S-901D (MIL-STD-901D)MIL-STD-167-1
Rugged computers, Diamond SystemsSabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300: designed to meet 810H shock and vibration. GEODE-JSP: 810H shock and vibration listedSabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300: 202H listed for the internal electronicsNot listedNot listed
Rugged Ethernet switches, Diamond SystemsSabreNet-12000: passed 810G shock and vibration. SabreNet-24000: 810 shock and vibration listedEPS-12002L, EPS-24G4X, SabreNet-12000, RS-EG8-002: 202G listedNot listedNot listed
Rugged Cisco networking, GET EngineeringCEN-6300, CEN-3300: designed to meet 810Not listedNot listedNot listed
VNX+ small form factor systems, GET EngineeringVNX+ System: designed to meet 810Not listedNot listedNot listed
NTDS over Ethernet, GET Engineering10094002-2P-CC-D-N-V: 810G Methods 507 and 506.5 listedNot listed10094002-2P-CC-D-N-V: MIL-S-901D Grade A listed10094002-2P-CC-D-N-V: 167-1A Type 1 listed
VPX enclosures, Dawn VME ProductsCCE-3VX1 to CCE-3VX6, ATR-5700: designed to 810E. ATR-6800: meets 810 shock and vibrationNot listedNot listedNot listed
VPX power supplies, Dawn VME ProductsPSC-6234: tested to 810 and VITA 47Not listedNot listedNot listed
Epsilon Systems AP West displays, Epsilon SystemsREP-10LED-PM, REP-10CPU-PM, REP-15IFL-115VAC, REP-17IFL-115VAC, REP-19LCD-RM115, REP-21HDW-115TV, REP-24HDW-10U115TV: listedNot listedREP-10LED-PM, REP-10CPU-PM, REP-19LCD-RM115, REP-21HDW-115TV, REP-24HDW-10U115TV: MIL-STD-901D Grade A, Class I, Type A listedREP-10LED-PM, REP-10CPU-PM, REP-19LCD-RM115, REP-21HDW-115TV, REP-24HDW-10U115TV: 167-1 Type 1 listed. REP-15IFL-115VAC, REP-17IFL-115VAC: 167-1 listed
DIT rugged displays and KVM rack drawers, DITMR17xx, MR19xx, MR20xx, MR24xx: 810G shock and vibration design. MGP173Mx, MD320Mx, MP1xx, MP2xx, MP3xx: designed to meet 810F/GNot listedMR17xx, MR19xx, MR20xx, MR24xx: 901D shock and vibration design. MGP173Mx, MD320Mx: designed to meet MIL-STD-901E Grade A or BMR17xx, MR19xx, MR20xx, MR24xx: 167 shock and vibration design. MGP173Mx, MD320Mx: designed to meet MIL-STD-167
Rugged UPS and frequency converters, Nova ElectricLineNot listedMIL-S-901: lineMIL-STD-167: line
Rugged inverters, Nova ElectricLineNot listedMIL-S-901: lineMIL-STD-167: line
Custom power supplies, Jasper ElectronicsCompactPCI supplies (PCI and DPCI series), GPAD-Series, HTL, HML and HAL modules, RPS rack supplies: offeredNot listedNot listedGPAD-Series: MIL-STD-167 offered

EMI and input power

Product family and manufacturerMIL-STD-461MIL-STD-704MIL-STD-1275MIL-STD-1399RTCA DO-160
Rugged computers, Diamond SystemsSabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300, GEODE-JSP: listedSabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300, GEODE-JSP: listedSabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300: listed. GEODE-JSP: with the optional supplyNot listedSabreCom-JRS, SabreCom-CE1: isolated power supply option
Rugged Ethernet switches, Diamond SystemsSabreNet-24000, SabreNet-12000: listed. RS-EG8-002: integrated filterSabreNet-24000, SabreNet-12000 (-2xx): listedSabreNet-24000, SabreNet-12000 (-2xx): listedNot listedNot listed
Rugged Cisco networking, GET EngineeringCEN-6300, CEN-3300: designed to meetCEN-6300, CEN-3300: 704F listedCEN-6300, CEN-3300: 1275D listedNot listedCEN-6300, CEN-3300: designed to meet
VNX+ small form factor systems, GET EngineeringVNX+ System: designed to meetNot listedNot listedNot listedNot listed
NTDS over Ethernet, GET Engineering10094002-2P-CC-D-N-V: 461F CE101, CS101, CS114 to CS116 listedNot listedNot listedNot listedNot listed
VPX enclosures, Dawn VME ProductsCCE-3VX1 to CCE-3VX6, ATR-5700: designed to 461ENot listedNot listedNot listedCCE-3VX1 to CCE-3VX6, ATR-5700: designed to DO-160E
VPX power supplies, Dawn VME ProductsNot listedPSC-6234: 704F listed except the 50 ms hold-up, which HLD-6724 adds. HLD-6724, HLD-6726: 50 ms hold-up to 704. HLD-6262: 50 ms hold-up to 704F. PSC-8742: integrated 50 ms hold-up to 704Not listedNot listedNot listed
Epsilon Systems AP West displays, Epsilon SystemsREP-10LED-PM, REP-10CPU-PM, REP-19LCD-RM115, REP-21HDW-115TV: 461E listed. REP-15IFL-115VAC, REP-17IFL-115VAC, REP-24HDW-10U115TV: 461F listedNot listedNot listedNot listedNot listed
DIT rugged displays and KVM rack drawers, DITMGP173Mx, MD320Mx: designed to meet 461F/G (CE102, RE101, RE102, CS101, CS114, CS116, RS101, RS103). MP1xx, MP2xx, MP3xx: designed to meet 461F/G CE102, RE102. MR17xx, MR19xx, MR20xx, MR24xx: 461G EMI glass offeredNot listedNot listedNot listedNot listed
Rugged UPS and frequency converters, Nova ElectricLineNot listedNot listedLineGRSLPFC Aircraft Grade UPS: DO-160 listed
Rugged inverters, Nova ElectricLineNot listedLine; the NGL-MIL Series takes 20 to 32 VDC vehicle inputNot listedNGL-Series (RTCA/DO-160 Qualified)
EMI filters and PDUs, Nova ElectricCustom filters designed to bring equipment under the CE102 limit; passive filters for CE101; PDUs with filtering to 461Not listedNot listedPassive filters: listedNot listed

Interface standards

Product family and manufacturerMIL-STD-1553MIL-STD-1397 (NTDS)MIL-STD-188-203-1A (ATDS)
MIL-STD-1553 and ARINC 429 interface hardware, AIMAPE1553-x (PCIe), AXC1553-x and AXE1553-x (XMC), AMCX1553-x and AMCE1553-x (PMC), ACE1553-3U-x (CPCIe/PXIe), AVC1553-x (VME), ASC1553 (USB), ANET1553-x (Ethernet) and moreNot listedNot listed
PBA.pro databus software, AIMPBA.pro-MILNot listedNot listed
Embedded IP cores, NOLAM Embedded SystemsNES-IPCORE-M1553 (bus controller, remote terminal and monitor)Not listedNot listed
Rugged computers, Diamond SystemsSabreCom-JSP, SabreCom-JRS: 1553 minicard I/O optionNot listedNot listed
VNX+ and Compact Embedded Systems, GET EngineeringVNX+ MiniPCIe I/O Module, VNX+ Protocols Module, Mission Computer CES, Multi-Protocol CESMission Computer CESMission Computer CES
NTDS interfaces, GET EngineeringNot listedMIL-STD-1397C adapters such as 10075001 (PCIe parallel); Virtual NTDS (V-NTDS); 10094002-2P-CC-D-N-V10072201 (PCI ATDS adapter, TADIL-A)

How to choose

The standard number is where a requirement starts, not where it ends. Four checks settle most selections:

  1. Name the method and the level. For MIL-STD-810, that means the method numbers (for example 514 vibration, 516 shock, 507 humidity) and the levels from your platform's tailoring. For MIL-STD-461, it means which requirements apply (CE102, CS114, RE102, RS103) and the platform limits. Compare those numbers with the test report, not with the headline on the datasheet.
  2. Match the revision letter. A program may call out MIL-STD-461G while a datasheet cites 461E. That is not automatically a mismatch; the question is whether the tested levels cover yours, and the manufacturer's test data answers it.
  3. Read the verb. "Designed to meet" says the unit was engineered for the condition. "Tested to" and "passed" say a test was run. "Qualified to" usually means a formal test with a report. Ask which applies to the exact configuration you will buy.
  4. Separate box from system. MIL-STD-461 and MIL-STD-1275 results depend on cabling, grounding and the platform's power, and MIL-S-901D results depend on mounting (Class I hard mounted, Class II on resilient mounts). A qualified box lowers the risk; the installed system is what gets tested.

These questions are easiest to answer while the design is still open. NewTec Reps works alongside your engineers at that stage: matching the platform's tailored levels to the models above, getting datasheets and test data from the manufacturer and bringing the manufacturer's engineers in when a level needs a closer look.

Frequently asked questions

What is the difference between MIL-STD-810 tested and MIL-STD-810 compliant?

MIL-STD-810 is a set of test methods that each program tailors, so neither word means much until the methods and levels are named. "Tested to" means the unit went through specific methods, ideally with a report you can read; "designed to meet" or "compliant" means the manufacturer engineered it for those conditions without necessarily testing that configuration. Ask for the method numbers, the levels and the test report, and compare them with your platform's tailored requirement.

Which military standards cover vehicle power?

MIL-STD-1275 defines 28 VDC power on military ground vehicles, and MIL-STD-704 defines aircraft power, including 28 VDC, 270 VDC and 115 VAC 400 Hz. Shipboard AC power falls under MIL-STD-1399 Section 300. Diamond Systems SabreCom computers, GET Engineering CEN-6300 and CEN-3300 systems and Nova Electric rugged inverters list MIL-STD-1275, and Dawn VME Products hold-up modules provide 50 ms of hold-up for MIL-STD-704.

What does COTS mean in defense procurement?

COTS means commercial off-the-shelf. The Federal Acquisition Regulation (FAR 2.101) defines a commercially available off-the-shelf item as a commercial product sold in substantial quantities in the commercial marketplace and offered to the government without modification. In rugged embedded hardware the term is used more broadly for standard catalog products built for military environments, as opposed to a custom design funded by the program.

Can COTS hardware meet MIL-STD-461?

Yes. Several COTS products in this catalog are designed to MIL-STD-461 or list it on their datasheets, including Dawn VME Products CCE-3VX cube enclosures (461E), DIT MGP173Mx and MD320Mx displays (461F/G), Diamond Systems SabreCom computers and GET Engineering CEN-6300 and CEN-3300 systems. Compliance still belongs to the installed system, because cabling, grounding and the platform's power affect the result, and Nova Electric designs custom CE102 filters when a system scan fails.

Have a requirement or a part number?

Speak to an Engineer who knows these product lines. Send what you have, even if it is only a rough spec, and we will come back with the models that fit.

Send the standard, its revision letter and the methods and levels your platform calls for, or a part number to check against them.

Speak to an Engineer

Talk through your requirement with an engineer

Tell us what you are building and what it has to survive. It is fine to come early, while the requirement is still open. We will match it to the right model, check the standards and interfaces, and get you a quote from the manufacturer when you are ready for one.

Fields marked * are required.

A part number, a rough spec or a question is enough.
Add company and other details (optional)

We use your details only to answer this request and may share them with the manufacturer you ask about. Privacy policy.