Diamond Systems
MIL-STD-810H rugged mission computers from Diamond Systems
A rugged mission computer is a sealed computer built to run on platform power through shock, vibration, water and temperature extremes. Diamond Systems makes five COTS models (SabreCom-JSP, SabreCom-JRS, SabreCom-CE1, SabreCom-300 and GEODE-JSP), all IP67 and designed to meet MIL-STD-810H (MIL-STD-810) shock and vibration, with MIL-STD-461, -704 and -1275 power options. NewTec Reps represents Diamond Systems.
Overview
What makes Diamond's rugged mission computers different from a board in a box?
Diamond builds the SabreCom-JSP, SabreCom-JRS, SabreCom-CE1 and GEODE-JSP around a COM Express module on its own carrier (the Jasper SBC in the SabreCom-JSP, SabreCom-JRS and GEODE-JSP). If a processor goes end of life, a new COM can be fitted with no mechanical change, according to Diamond. The SabreCom-300 is built around Diamond's Jasper or Venus SBC. The enclosures are CNC aluminum with MIL-DTL-38999 connectors and IP67 sealing.
Which standards do they address?
Diamond states the SabreCom systems are designed to meet MIL-STD-810H shock and vibration, with internal electronics qualified to MIL-STD-202H. Power options are a MIL-STD-461 filter module or an isolated MIL supply with MIL-STD-461, -704 and -1275 compliance (DO-160 is also listed on the SabreCom-JRS and SabreCom-CE1). On the SabreCom-JRS and SabreCom-CE1 that choice matters: the isolated supply carries the MIL-STD-704 aircraft power and MIL-STD-1275 vehicle power compliance, while the lower-cost filter module covers MIL-STD-461 on a 12 VDC or 18-24 VDC input. For how these standards map across product types, see MIL-STD COTS hardware.
Products and manufacturers
NewTec Reps represents Diamond Systems for these computers:
| Model | What it is | Best fit |
|---|---|---|
| SabreCom-JSP | Rugged x86 computer with the most expansion (up to 6 minicards, or 2 minicards plus PCIe/104) | Custom I/O, 1553, CAN, analog |
| SabreCom-JRS | Compact rugged x86 computer with predefined I/O options | Smallest enclosure, short lead time |
| SabreCom-CE1 | Computer plus Layer 3 managed switch with 10GbE, removable SSD | One box for compute and network |
| SabreCom-300 | Computer plus 7 or 15 port Gigabit switch | Compute plus a Layer 2 switch |
| GEODE-JSP | Quick-ship rugged computer on Jasper | Fast delivery of a standard build |
For GPU computing in an enclosure, see the JetBox OSBOURNE (listed Coming Soon by Diamond) on the Jetson page. For a sealed switch without a computer, see SabreNet-24000 on the Ethernet switch page.
Non-Diamond options
NewTec Reps also represents GET Engineering for small form factor SOSA systems (VNX+), high-density I/O, NTDS and rugged Cisco networking. See VNX+ small form factor SOSA systems, GET Engineering products, FPGA and high-density I/O and rugged Cisco networking.
For the operator station, NewTec Reps also represents DIT (Display Integration Technologies), whose PPC panel PCs build the computer into the display and whose 1U KVM rack drawers switch one keyboard and screen across up to 32 computers; see DIT panel PCs and KVM rack drawers. Epsilon Systems makes the REP-10CPU-PM, a 10.4 in rugged display with a built-in CPU; see Epsilon Systems AP West displays.
Specifications
| Model | Processor | RAM / storage | Standard I/O | Operating temp | Power input | Size (W x D x H) | Source | Ask an engineer |
|---|---|---|---|---|---|---|---|---|
SabreCom-JSP | Core i7 or Xeon, 11th or 13th gen | 32-64 GB (ECC option) / 128 GB-2 TB M.2 | 2x GbE, 1-3x USB 3.0, 2x USB 2.0, 4x RS-232/422/485, HDMI, audio | -40 to +80 C | 10-60 VDC | 254 x 188 x 77 mm | Diamond | Ask an engineer |
SabreCom-JRS | Core i7 or Xeon, 11th or 13th gen | 32-64 GB (ECC option) / 128 GB-2 TB | 2x GbE, 1-3x USB 3.0, 2x USB 2.0, 4x RS-232/422/485, HDMI, 28 GPIO | -40 to +80 C | 12 or 18-24 VDC (filter); 10-60 VDC (isolated) | 200 x 186 x 80 mm | Diamond | Ask an engineer |
SabreCom-CE1 | Core i7 or Xeon, 11th or 13th gen | 32-64 GB (ECC option) / 128 GB-2 TB removable | 11x 1GbE + 1 or 2x 10GbE switch, 1x GbE, 4x USB 2.0, 4x RS-232/422/485, HDMI, 8 GPIO | -40 to +75 C | 12 or 18-24 VDC (filter); 10-60 VDC (isolated) | 284 x 218 x 109 mm | Diamond | Ask an engineer |
SabreCom-300 | Core i7, 7th, 11th or 13th gen | 20-64 GB / 128 GB-2 TB SATA | 7 or 15x 1GbE switch, USB 3.0/2.0, serial, HDMI, GPIO | -40 to +75 C | 9-60 VDC (isolated) | 111 x 174 x 237 mm (W x H x D, incl. feet) | Diamond | Ask an engineer |
GEODE-JSP | 11th gen Core i7 base (others optional) | 64 GB base / M.2 up to 2 TB | 2x GbE, 3x USB 3.0, 2x USB 2.0, 4x RS-232/422/485, HDMI, up to 110 expansion signals | -40 to +80 C | 9-60 VDC | 230 x 179 x 104 mm, 2.6 kg | Diamond | Ask an engineer |
All five are IP67. Maximum system dissipation is 80 W on the SabreCom-JRS and SabreCom-CE1 isolated supply option.
How to choose
Start from the I/O list and the power bus. These are COTS systems with configurable options: the SabreCom-JRS and SabreCom-CE1 have predefined I/O configurations with no NRE, the SabreCom-JSP takes the most minicard and PCIe/104 expansion for custom I/O, and the GEODE-JSP is Diamond's quick-ship build. Bring the requirement while the design is still open and NewTec Reps will map it to a configuration, with Diamond's engineers involved where the I/O is unusual.
| Requirement | Qualifying models |
|---|---|
| Smallest published enclosure | SabreCom-JRS |
| Integrated managed switch | SabreCom-CE1 (Layer 3, 10GbE), SabreCom-300 (Layer 2, 1GbE) |
| 10GbE fiber or copper on the box | SabreCom-CE1 |
| Removable SSD | SabreCom-CE1 |
| PCIe/104 expansion | SabreCom-JSP, SabreCom-300, GEODE-JSP |
| MIL-STD-1553 via minicard | SabreCom-JSP, SabreCom-JRS, SabreCom-CE1 |
| -40 to +80 C operation | SabreCom-JSP, SabreCom-JRS, GEODE-JSP |
| Optional 16-bit A/D and D/A | SabreCom-JSP, SabreCom-JRS, GEODE-JSP, SabreCom-300 (Jasper SBC) |
| DO-160 listed on power option | SabreCom-JRS, SabreCom-CE1 |
| MIL-STD-704 and MIL-STD-1275 power input | SabreCom-JSP, SabreCom-300; SabreCom-JRS and SabreCom-CE1 with the isolated MIL supply; GEODE-JSP (MIL-STD-1275 with the optional supply) |
Which rugged mission computer has a 10GbE switch and IP67 sealing?
The Diamond Systems SabreCom-CE1. It pairs a Core i7 or Xeon COM Express computer with an 11-port 1GbE plus 1 or 2 port 10GbE Layer 3 switch in one IP67 enclosure. The 10G ports come as copper or fiber connector options (CR1, CM2, FX2, FT2).
Which rugged computer can take a dual redundant MIL-STD-1553 card?
Diamond lists a dual redundant MIL-STD-1553 minicard option for the SabreCom-JSP, and names MIL-STD-1553 and ARINC 429 among the Diamond and third-party minicard options for the SabreCom-JRS and SabreCom-CE1. Ask NewTec Reps which predefined I/O configuration includes it.
Which Diamond rugged computer ships fastest?
Diamond describes the GEODE-JSP as its quick-ship rugged system and lists predefined, no-NRE I/O configurations with reduced lead time for the SabreCom-JRS and SabreCom-CE1.
Applications
Diamond describes the SabreCom-JRS and SabreCom-CE1 as suited to harsh environment and mobile applications, and the SabreCom-JSP to military and rugged applications. Uses include mission and control computing, gateway and network computing (SabreCom-CE1, SabreCom-300) and data acquisition with on-board 16-bit analog I/O.
Frequently asked questions
What is a rugged mission computer?
A rugged mission computer is a sealed computer designed to operate on platform power under shock, vibration, moisture and wide temperature ranges. Diamond's versions use IP67 enclosures, MIL-DTL-38999 connectors and Intel Core i7 or Xeon processors.
Can I change the processor later?
Diamond builds the SabreCom-JSP, SabreCom-JRS and SabreCom-CE1 on COM Express modules, and states that a new COM can replace an end-of-life one with no mechanical change and usually minimal OS driver work. Specific processor or COM vendor requests are handled for a nominal NRE.
What power input do Diamond rugged computers accept?
It depends on the power option. The isolated MIL supply accepts 10-60 VDC on the SabreCom-JSP, SabreCom-JRS and SabreCom-CE1, and 9-60 VDC on the SabreCom-300 and GEODE-JSP. A lower-cost MIL-STD-461 filter option accepts a fixed 12 VDC or 18-24 VDC on the JRS and CE1.
Are these computers tested to MIL-STD-810H?
Diamond states the SabreCom systems are designed to meet MIL-STD-810H shock and vibration and that internal electronics are qualified to MIL-STD-202H. Diamond rates the GEODE-JSP for MIL-STD-810H shock and vibration and publishes a Geode shock and vibration test report. For the SabreCom-JSP it points to the Geode test results, and for the SabreCom-JRS and SabreCom-CE1 it links a shock and vibration test report on similar products.
Which Diamond rugged computers include an Ethernet switch?
The SabreCom-CE1 and the SabreCom-300. The SabreCom-CE1 has a Layer 3 managed switch with 11 1GbE ports and 1 or 2 10GbE ports, and the SabreCom-300 has a Layer 2 managed switch with 7 or 15 1GbE ports.
Can I order an evaluation unit of a SabreCom or GEODE rugged computer?
Yes. Evaluation units are purchased through NewTec Reps, the same way as production quantities. Speak to an Engineer for a quote.
Related pages
Have a requirement or a part number?
Speak to an Engineer who knows these product lines. Send what you have, even if it is only a rough spec, and we will come back with the models that fit.
Send the model (for example SabreCom-JRS), your processor and memory choice, I/O list, power input and environmental requirements. NewTec Reps will confirm the Diamond configuration and return a quote.
Your message is with an engineer
Thanks. We have your note about Rugged Computers. An engineer from NewTec Reps will reply to the email address you gave us.
What happens next:
- An engineer reads your message and checks it against the product lines we represent.
- We reply with the models that fit, the datasheets and any questions we need answered.
- When you are ready for pricing, we get you a quote from the manufacturer.